79902

This special indoor cable with bend-insensitive fibre G.657.A2, protected by easy strippable soft tube, meets all requirements for modern building cabling: a small diameter, low weight, high tensile force and excellent bend and crush performance. Its easy, fast strippable sheath consist of special flame retardant LSZH-material, making the cable extremely robust, but flexible, with its 90° bend radius capability. Consequently, the STIC is perfectly suitable to be installed on the wall by using e.g. staples or glue. Due to its (semi-)dry construction, this cable is highly safe and can be used in any human habitation. The dry soft tube makes also easier its installation into the vertical riser shafts of MDU’s.
STIC Dca
24x SM G.657.A2 (2x12)

Specifications

Product characteristics
Cable type STC
Fibre type Single mode 9/125
Optical fibre standard ITU-T G.657.A2
Number of fibers 24
Number of fibers per optical element 12
Optical element Soft tube
Cable metal free Yes
Stripability outer sheath 1000 mm
Stripability optical element > 1000 mm, down to primary coating
Strain relief Yes
Type of strain relief Aramid fibre
Material outer sheath HFFR
Colour outer sheath White
Outer sheath thickness 0,35 mm
Outer diameter approx. 4,0 mm
Marking ACE - TKF - STIC Dca 24 x SM G.657.A2 - (2x12) - 79902 {Batch} [-CE-] DoP: 0053 {Year} {Length} M
Application
Test procedures EN IEC 60794-1-2
Standardization EN IEC 60794-2
Application Inside
Suitable for indoor installation Simulated according IEC 60794-1-21 E27
Euro fire class according to EN 13501-6 Dca
Euro class smoke production according to EN 13501-6 s2
Euro class flaming droplets/particles according to EN 13501-6 d2
Euro class acidity according to EN 13501-6 a1
Mechanical specification
Tensile load short term (Tm) 300 N
Max. fiber strain at Tm 0,6 %
Tensile load Long Term (Tl) 100 N
Min. bending radius during installation 50 mm
Min. bending radius after installation 30 mm
Crush resistance E3A short (1min) 500 N/dm
Crush resistance E3A long 300 N/dm
Crush load E3A long application time 10 min
Impact strength 1 J
Striking surface radius 12,5 mm
Torsion resistance 360 °/m
Kink resistance 10 mm
Optical specification
Category according to EN 50173 OS2
Max. attenuation @ 1310 nm 0,4 dB/km
Max. attenuation @ 1550 nm 0,3 dB/km
Max. attenuation @ 1625 nm 0,4 dB/km
Environmental specification
Longitudinal water blocking Yes
Longitudinal watertight construction Super Absorbing Polymer
Installation temperature -10/50 °C
Transportation and storage temperature -25/60 °C
Operational temperature range Ta1 - Tb1 -10/50 °C
Operational temperature range Ta2 - Tb2 -25/60 °C
TC sample length for TC acc. F1 or F12 50 m
Other specification
Halogen free (acc. EN 60754-1/2) Yes
Low smoke (acc. EN 61034-2) Yes
Caloric value 236 MJ/km
Logistical specifications
Unit meter
Netto Weight (kg/m) 0.014
Default packaging H X 4000/100