This special indoor cable with bend-insensitive fibre G.657.A2, protected by easy strippable soft tube, meets all requirements for modern building cabling:
a small diameter, low weight, high tensile force and excellent bend and crush performance.
Its easy, fast strippable sheath consist of special flame retardant LSZH-material, making the cable extremely robust, but flexible, with its 90° bend radius capability.
Consequently, the STIC is perfectly suitable to be installed on the wall by using e.g. staples or glue. Due to its (semi-)dry construction, this cable is highly safe and can be used in any human habitation.
The dry soft tube makes also easier its installation into the vertical riser shafts of MDU’s.
STIC Dca 1x SM G.657.A2
For current stock information you need to login. New to TKF Telecom? Please register here
Pdf
Specifications
Cable type
STC
Fibre type
Single mode 9/125
Optical fibre standard
ITU-T G.657.A2
Number of fibers
1
Number of fibers per optical element
1
Optical element
Soft tube
Cable metal free
Yes
Stripability outer sheath
1000 mm
Stripability optical element
> 1000 mm, down to primary coating
Strain relief
Yes
Type of strain relief
Aramid fibre
Material outer sheath
LSZH
Colour outer sheath
White
Outer sheath thickness
0,45 mm
Outer diameter approx.
2,9 mm
Marking
ACE - TKF - STIC Dca 1 x SM G.657.A2 - 79896 {Batch} [-CE-] DoP: 0053 {Year} {Length} M
Test procedures
EN IEC 60794-1-2
Standardization
EN IEC 60794-2
Application
Inside
Suitable for indoor installation
Simulated according IEC 60794-1-21 E27
Euro fire class according to EN 13501-6
Dca
Euro class smoke production according to EN 13501-6
s2
Euro class flaming droplets/particles according to EN 13501-6
d2
Euro class acidity according to EN 13501-6
a1
Tensile load short term (Tm)
300 N
Max. fiber strain at Tm
0,6 %
Tensile load Long Term (Tl)
100 N
Min. bending radius during installation
36 mm
Min. bending radius after installation
20 mm
Crush resistance E3A short (1min)
500 N/dm
Crush resistance E3A long
300 N/dm
Crush load E3A long application time
10 min
Impact strength
1 J
Striking surface radius
12,5 mm
Torsion resistance
360 °/m
Kink resistance
10 mm
Category according to EN 50173
OS2
Max. attenuation @ 1310 nm
0,4 dB/km
Max. attenuation @ 1550 nm
0,3 dB/km
Max. attenuation @ 1625 nm
0,4 dB/km
Longitudinal water blocking
Yes
Longitudinal watertight construction
Super Absorbing Polymer
Installation temperature
-10/50 °C
Transportation and storage temperature
-25/60 °C
Operational temperature range Ta1 - Tb1
-10/50 °C
Operational temperature range Ta2 - Tb2
-25/60 °C
TC sample length for TC acc. F1 or F12
50 m
Halogen free (acc. EN 60754-1/2)
Yes
Low smoke (acc. EN 61034-2)
Yes
Caloric value
120 MJ/km
Unit
meter
Netto Weight (kg/m)
0.007
Default packaging
H X 1000/50