74572

The Loose Tube Cable Rodent-Protected (LTC RP) is a robust, nonmetallic, loose tube outdoor duct cable, rodent protected, longitudinal water-protected, with high pulling force. Installation: by blowing or pulling, into conduits or on cable trays.
LTC RP
288x SM G.657.A1 ((9+15)x12)

Specifications

Product characteristics
Cable type LTC
Fibre type Single mode 9/125
Optical fibre standard ITU-T G.657.A1
Number of fibers 288
Number of fibers per optical element 12
Optical element Loose tube, gel filled
Cable metal free Yes
Number of layers 2 Layers
Strip method 1 Rip cord
Strain relief Yes
Material outer sheath HDPE
Colour outer sheath Black
Outer sheath thickness 1,6 mm
Outer diameter approx. 17,9 mm
Marking ACE - TKF LTC RP 288x SM G.657.A1 ((9+15)x12) A-DQ(ZN)B2Y 74572 {Batch} {Year} {Length}
Application
Test procedures EN IEC 60794-1-2
Standardization EN IEC 60794-3-10
Application Outside
Blow in Yes
Euro fire class according to EN 13501-6 Fca
Mechanical specification
Tensile load short term (Tm) 5000 N
Tensile load Long Term (Tl) 3000 N
Min. bending radius during installation 380 mm
Min. bending radius after installation 285 mm
Impact strength 7 J
Striking surface radius 10 mm
Torsion resistance 360 °/m
Optical specification
Category according to EN 50173 OS2
Max. attenuation @ 1310 nm 0,35 dB/km
Max. attenuation @ 1550 nm 0,22 dB/km
Max. attenuation @ 1625 nm 0,25 dB/km
Environmental specification
Longitudinal water blocking Yes
Longitudinal watertight construction Super Absorbing Polymer
Installation temperature -15/55 °C
Transportation and storage temperature -40/70 °C
Operational temperature range Ta1 - Tb1 -30/70 °C
Max. attenuation increase during Ta1 - Tb1 0,05 dB
Operational temperature range Ta2 - Tb2 -40/70 °C
Max. attenuation increase during Ta2 - Tb2 0,15 dB
UV resistant Yes
UV-protection ISO 4892/2
With rodent protection Yes
Other specification
Halogen free (acc. EN 60754-1/2) Yes
Logistical specifications
Unit meter
Netto Weight (kg/m) 0.242