The store will not work correctly in the case when cookies are disabled.
JavaScript seems to be disabled in your browser.
For the best experience on our site, be sure to turn on Javascript in your browser.
74560
The Loose Tube Cable Rodent-Protected (LTC RP) is a robust, nonmetallic, loose tube outdoor duct cable, rodent protected, longitudinal water-protected, with high pulling force. Installation: by blowing or pulling, into conduits or on cable trays.
LTC RP 48x SM G.657.A1 (6x8)
For current stock information you need to login. New to TKF Telecom? Please register here
Pdf
Specifications
Cable type
LTC
Fibre type
Single mode 9/125
Optical fibre standard
ITU-T G.657.A1
Number of fibers
48
Number of fibers per optical element
8
Optical element
Loose tube, gel filled
Cable metal free
Yes
Number of layers
1 Layer
Strip method
1 Rip cord
Strain relief
Yes
Type of strain relief
FRP + E-glass
Material outer sheath
HDPE
Colour outer sheath
Black
Outer sheath thickness
1,5 mm
Outer diameter approx.
10,8 mm
Marking
ACE - TKF LTC RP 48x SM G.657.A1 (6x8) A-DQ(ZN)B2Y 74560 {Batch} {Year} {Length}
Test procedures
EN IEC 60794-1-2
Standardization
EN IEC 60794-3-10
Application
Outside
Blow in
Yes
Euro fire class according to EN 13501-6
Fca
Tensile load short term (Tm)
4500 N
Max. cable strain at Tm
0,8 %
Max. fiber strain at Tm
0,1 %
Tensile load Long Term (Tl)
4000 N
Max. fiber strain at Tl
0,0 %
Min. bending radius during installation
215 mm
Min. bending radius after installation
160 mm
Impact strength
5 J
Striking surface radius
10 mm
Torsion resistance
360 °/m
Category according to EN 50173
OS2
Max. attenuation @ 1310 nm
0,35 dB/km
Max. attenuation @ 1550 nm
0,22 dB/km
Max. attenuation @ 1625 nm
0,25 dB/km
Longitudinal water blocking
Yes
Longitudinal watertight construction
Super Absorbing Polymer
Installation temperature
-15/55 °C
Transportation and storage temperature
-40/70 °C
Operational temperature range Ta1 - Tb1
-30/70 °C
Max. attenuation increase during Ta1 - Tb1
0,05 dB
Operational temperature range Ta2 - Tb2
-40/70 °C
Max. attenuation increase during Ta2 - Tb2
0,15 dB
TC sample length for TC acc. F1 or F12
1000 m
UV resistant
Yes
UV-protection
ISO 4892/2
With rodent protection
Yes
Halogen free (acc. EN 60754-1/2)
Yes
Unit
meter
Netto Weight (kg/m)
0.095